Review



mouse rectal probe  (World Precision Instruments)


Bioz Verified Symbol World Precision Instruments is a verified supplier
Bioz Manufacturer Symbol World Precision Instruments manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    World Precision Instruments mouse rectal probe
    Mouse Rectal Probe, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 93/100, based on 46 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/Rodent+Rectal+Temperature+Probe-For+Mouse/pm43046227-259-11-15
    Average 93 stars, based on 46 article reviews
    mouse rectal probe - by Bioz Stars, 2026-11
    93/100 stars

    Images

    Related Articles

    Insulation:

    Article Title: Autophagy-regulating bioactive nanoparticle alleviates MASH via gut-liver axis-mediated mitochondria/cAMP/GLP1 pathway.
    Article Snippet: The mice were single-housed with unlimited water.The mice were single-housed with unlimited water.. Core body temperature was monitored at numerous time points using a mouse rectal probe (RET3; World Precision Instruments).

    Article Title: Microglial CHOP expression contributes to the consequences of Ethanol Withdrawal
    Article Snippet: to ensure subject health. To measure the effects of CIE exposure on thermoregulation, core body temperatures of experimental mice were measured using a rectal probe connected to a digital thermometer (World Precision Instruments; #RET-3 and #BAT-12R). The probe was inserted 2cm into the colon for a period of no longer than 30 s. Mice were habituated to temperature measurements before starting CIE t

    Article Title: The 18S rRNA methyltransferase, BUD23, is required for appropriate lipid and mitochondrial metabolism
    Article Snippet: temperature was calculated using Flir Tools software, where the average temperature was measured from a minimum of four images per mouse. .. Rectal temperature of unanaesthetised AD mice was measured using mouse rectal probe (RET-3, Type T Thermocouple, World Precision Instruments) connected to a BAT-12 Microprobe Thermometer (Physitemp Instruments). .. Recording of body temperature and activity was carried out via surgically implanted radiotelemetry devices (TA-F10, Data Sciences International).

    Article Title: Loss of the alternative calcineurin variant CnAβ1 enhances brown adipocyte differentiation and drives metabolic overactivation through FoxO1 activation
    Article Snippet: Body temperature of mice was measured using a rectal probe (Ref. RET-3, World Precision Instruments) and interscapular BAT (iBAT) temperature was determined with a thermographic camera (T420, FLIR ® ). .. F

    Control:

    Article Title: Autophagy-regulating bioactive nanoparticle alleviates MASH via gut-liver axis-mediated mitochondria/cAMP/GLP1 pathway.
    Article Snippet: The mice were single-housed with unlimited water.The mice were single-housed with unlimited water.. Core body temperature was monitored at numerous time points using a mouse rectal probe (RET3; World Precision Instruments).

    Article Title: Microglial CHOP expression contributes to the consequences of Ethanol Withdrawal
    Article Snippet: to ensure subject health. To measure the effects of CIE exposure on thermoregulation, core body temperatures of experimental mice were measured using a rectal probe connected to a digital thermometer (World Precision Instruments; #RET-3 and #BAT-12R). The probe was inserted 2cm into the colon for a period of no longer than 30 s. Mice were habituated to temperature measurements before starting CIE t

    Article Title: The 18S rRNA methyltransferase, BUD23, is required for appropriate lipid and mitochondrial metabolism
    Article Snippet: temperature was calculated using Flir Tools software, where the average temperature was measured from a minimum of four images per mouse. .. Rectal temperature of unanaesthetised AD mice was measured using mouse rectal probe (RET-3, Type T Thermocouple, World Precision Instruments) connected to a BAT-12 Microprobe Thermometer (Physitemp Instruments). .. Recording of body temperature and activity was carried out via surgically implanted radiotelemetry devices (TA-F10, Data Sciences International).

    Article Title: Loss of the alternative calcineurin variant CnAβ1 enhances brown adipocyte differentiation and drives metabolic overactivation through FoxO1 activation
    Article Snippet: Body temperature of mice was measured using a rectal probe (Ref. RET-3, World Precision Instruments) and interscapular BAT (iBAT) temperature was determined with a thermographic camera (T420, FLIR ® ). .. F

    Mouse Assay:

    Article Title: Autophagy-regulating bioactive nanoparticle alleviates MASH via gut-liver axis-mediated mitochondria/cAMP/GLP1 pathway.
    Article Snippet: The mice were single-housed with unlimited water.The mice were single-housed with unlimited water.. Core body temperature was monitored at numerous time points using a mouse rectal probe (RET3; World Precision Instruments).

    Article Title: Microglial CHOP expression contributes to the consequences of Ethanol Withdrawal
    Article Snippet: to ensure subject health. To measure the effects of CIE exposure on thermoregulation, core body temperatures of experimental mice were measured using a rectal probe connected to a digital thermometer (World Precision Instruments; #RET-3 and #BAT-12R). The probe was inserted 2cm into the colon for a period of no longer than 30 s. Mice were habituated to temperature measurements before starting CIE t

    Article Title: The 18S rRNA methyltransferase, BUD23, is required for appropriate lipid and mitochondrial metabolism
    Article Snippet: temperature was calculated using Flir Tools software, where the average temperature was measured from a minimum of four images per mouse. .. Rectal temperature of unanaesthetised AD mice was measured using mouse rectal probe (RET-3, Type T Thermocouple, World Precision Instruments) connected to a BAT-12 Microprobe Thermometer (Physitemp Instruments). .. Recording of body temperature and activity was carried out via surgically implanted radiotelemetry devices (TA-F10, Data Sciences International).

    Article Title: Loss of the alternative calcineurin variant CnAβ1 enhances brown adipocyte differentiation and drives metabolic overactivation through FoxO1 activation
    Article Snippet: Body temperature of mice was measured using a rectal probe (Ref. RET-3, World Precision Instruments) and interscapular BAT (iBAT) temperature was determined with a thermographic camera (T420, FLIR ® ). .. F

    Software:

    Article Title: Autophagy-regulating bioactive nanoparticle alleviates MASH via gut-liver axis-mediated mitochondria/cAMP/GLP1 pathway.
    Article Snippet: The mice were single-housed with unlimited water.The mice were single-housed with unlimited water.. Core body temperature was monitored at numerous time points using a mouse rectal probe (RET3; World Precision Instruments).

    Article Title: Microglial CHOP expression contributes to the consequences of Ethanol Withdrawal
    Article Snippet: to ensure subject health. To measure the effects of CIE exposure on thermoregulation, core body temperatures of experimental mice were measured using a rectal probe connected to a digital thermometer (World Precision Instruments; #RET-3 and #BAT-12R). The probe was inserted 2cm into the colon for a period of no longer than 30 s. Mice were habituated to temperature measurements before starting CIE t

    Article Title: The 18S rRNA methyltransferase, BUD23, is required for appropriate lipid and mitochondrial metabolism
    Article Snippet: temperature was calculated using Flir Tools software, where the average temperature was measured from a minimum of four images per mouse. .. Rectal temperature of unanaesthetised AD mice was measured using mouse rectal probe (RET-3, Type T Thermocouple, World Precision Instruments) connected to a BAT-12 Microprobe Thermometer (Physitemp Instruments). .. Recording of body temperature and activity was carried out via surgically implanted radiotelemetry devices (TA-F10, Data Sciences International).

    Article Title: Loss of the alternative calcineurin variant CnAβ1 enhances brown adipocyte differentiation and drives metabolic overactivation through FoxO1 activation
    Article Snippet: Body temperature of mice was measured using a rectal probe (Ref. RET-3, World Precision Instruments) and interscapular BAT (iBAT) temperature was determined with a thermographic camera (T420, FLIR ® ). .. F

    Activity Assay:

    Article Title: Autophagy-regulating bioactive nanoparticle alleviates MASH via gut-liver axis-mediated mitochondria/cAMP/GLP1 pathway.
    Article Snippet: The mice were single-housed with unlimited water.The mice were single-housed with unlimited water.. Core body temperature was monitored at numerous time points using a mouse rectal probe (RET3; World Precision Instruments).

    Article Title: Microglial CHOP expression contributes to the consequences of Ethanol Withdrawal
    Article Snippet: to ensure subject health. To measure the effects of CIE exposure on thermoregulation, core body temperatures of experimental mice were measured using a rectal probe connected to a digital thermometer (World Precision Instruments; #RET-3 and #BAT-12R). The probe was inserted 2cm into the colon for a period of no longer than 30 s. Mice were habituated to temperature measurements before starting CIE t

    Article Title: The 18S rRNA methyltransferase, BUD23, is required for appropriate lipid and mitochondrial metabolism
    Article Snippet: temperature was calculated using Flir Tools software, where the average temperature was measured from a minimum of four images per mouse. .. Rectal temperature of unanaesthetised AD mice was measured using mouse rectal probe (RET-3, Type T Thermocouple, World Precision Instruments) connected to a BAT-12 Microprobe Thermometer (Physitemp Instruments). .. Recording of body temperature and activity was carried out via surgically implanted radiotelemetry devices (TA-F10, Data Sciences International).

    Article Title: Loss of the alternative calcineurin variant CnAβ1 enhances brown adipocyte differentiation and drives metabolic overactivation through FoxO1 activation
    Article Snippet: Body temperature of mice was measured using a rectal probe (Ref. RET-3, World Precision Instruments) and interscapular BAT (iBAT) temperature was determined with a thermographic camera (T420, FLIR ® ). .. F

    Injection:

    Article Title: Autophagy-regulating bioactive nanoparticle alleviates MASH via gut-liver axis-mediated mitochondria/cAMP/GLP1 pathway.
    Article Snippet: The mice were single-housed with unlimited water.The mice were single-housed with unlimited water.. Core body temperature was monitored at numerous time points using a mouse rectal probe (RET3; World Precision Instruments).

    Article Title: Microglial CHOP expression contributes to the consequences of Ethanol Withdrawal
    Article Snippet: to ensure subject health. To measure the effects of CIE exposure on thermoregulation, core body temperatures of experimental mice were measured using a rectal probe connected to a digital thermometer (World Precision Instruments; #RET-3 and #BAT-12R). The probe was inserted 2cm into the colon for a period of no longer than 30 s. Mice were habituated to temperature measurements before starting CIE t

    Article Title: The 18S rRNA methyltransferase, BUD23, is required for appropriate lipid and mitochondrial metabolism
    Article Snippet: temperature was calculated using Flir Tools software, where the average temperature was measured from a minimum of four images per mouse. .. Rectal temperature of unanaesthetised AD mice was measured using mouse rectal probe (RET-3, Type T Thermocouple, World Precision Instruments) connected to a BAT-12 Microprobe Thermometer (Physitemp Instruments). .. Recording of body temperature and activity was carried out via surgically implanted radiotelemetry devices (TA-F10, Data Sciences International).

    Article Title: Loss of the alternative calcineurin variant CnAβ1 enhances brown adipocyte differentiation and drives metabolic overactivation through FoxO1 activation
    Article Snippet: Body temperature of mice was measured using a rectal probe (Ref. RET-3, World Precision Instruments) and interscapular BAT (iBAT) temperature was determined with a thermographic camera (T420, FLIR ® ). .. F



    Similar Products

    93
    World Precision Instruments mouse rectal probe
    Mouse Rectal Probe, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/Rodent+Rectal+Temperature+Probe-For+Mouse/pm43046227-259-11-15
    Average 93 stars, based on 1 article reviews
    mouse rectal probe - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    93
    World Precision Instruments rodent rectal temperature probe-for mouse
    Rodent Rectal Temperature Probe For Mouse, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/Rodent+Rectal+Temperature+Probe-For+Mouse/custom%40ret-3%4010%2E1016%2Fj%2Eaddicn%2E2026%2E100269
    Average 93 stars, based on 1 article reviews
    rodent rectal temperature probe-for mouse - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    86
    Physitemp probe ret 3 probe
    Probe Ret 3 Probe, supplied by Physitemp, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/3+probe+probe+ret/pmc12977192-55-19-13
    Average 86 stars, based on 1 article reviews
    probe ret 3 probe - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Kent Scientific Corp rodent rectal temperature probe ret 3
    Rodent Rectal Temperature Probe Ret 3, supplied by Kent Scientific Corp, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/probe+rectal+temperature/10__7150_slash_ijbs__122643-54-11-17
    Average 86 stars, based on 1 article reviews
    rodent rectal temperature probe ret 3 - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Braintree Scientific probe ret 3
    Probe Ret 3, supplied by Braintree Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/braintree+inserted+scientific/pm41348539-256-9-9
    Average 86 stars, based on 1 article reviews
    probe ret 3 - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Physitemp ret 3 probes
    Ret 3 Probes, supplied by Physitemp, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/3+ret+%D0%B2%D1%81%D0%B5%D1%85+%D0%B3%D1%80%D1%83%D0%BF%D0%BF+%D0%B4%D0%B0%D1%82%D1%87%D0%B8%D0%BA%D0%B0+%D0%B6%D0%B8%D0%B2%D0%BE%D1%82%D0%BD%D1%8B%D1%85+%D0%B8%D0%B7%D0%BC%D0%B5%D1%80%D1%8F%D0%BB%D0%B8+%D0%B8%D1%81%D0%BF%D0%BE%D0%BB%D1%8C%D0%B7%D0%BE%D0%B2%D0%B0%D0%BD%D0%B8%D0%B5%D0%BC+%D0%BC%D1%8B%D1%88%D1%86%D1%8B+%D1%81+%D1%81%D0%B5%D1%80%D0%B4%D0%B5%D1%87%D0%BD%D0%BE%D0%B9+%D1%82%D0%B5%D0%BC%D0%BF%D0%B5%D1%80%D0%B0%D1%82%D1%83%D1%80%D1%83+%D1%82%D0%BE%D1%87%D0%B5%D1%87%D0%BD%D0%BE+%D1%83/pm41248820-79-9-11
    Average 86 stars, based on 1 article reviews
    ret 3 probes - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    Physitemp ret-3 rectal probe for mice
    Ret 3 Rectal Probe For Mice, supplied by Physitemp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/rectal+probe+ret+3/pmc12211996-317-10-11
    Average 90 stars, based on 1 article reviews
    ret-3 rectal probe for mice - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Kent Scientific Corp rectal probe for mice ret-3
    Rectal Probe For Mice Ret 3, supplied by Kent Scientific Corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ret-3/ret+3+rectal+probe/pm40595405-298-18-19
    Average 90 stars, based on 1 article reviews
    rectal probe for mice ret-3 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results